We are looking for a collet clamp type SCPJWP90-6000. In the specification is written clamping load of 6kN with operating air pressure of 0,5 MPa.
Do you have data available what would be the clamping force in case we apply 0,1 / 0,2 / 0,3 / 0,4 MPA?
If the air pressure is too low, the jaw will not work, and if it is too high, the internal part will break, so it must be in the range of 0.45-0.55 MPa. So, you can not use this product with 0,1 / 0,2 / 0,3 / 0,4 MPa.
And the clamping force with 0,45 MPa would be 5,4 kN and 0,55 MPa would be 6,6 kN.
For more informations, please download the catalogue and contact our team.